Bibliotheek
Presentaties ASCRS 2011, San Diego
Dr. Vryghem - Early results with the implantation of a new trifocal diffractive IOL

Dr. Gatinel - Principles and Evaluation of Image Quality of diffrctive Trifocal IO
Dr. Lesieur - Depth of field and multifocal IOL
Dr. Rozot - Near, intermediate and far vision with a new trifocal IOL early results with the first patients
Pr. Cochener - Photopic versus mesopic outcomes with a new pupil dependant trifocal IOL
Development of the PhysIOL 123 Preloaded IOL System C.
Pagnoulle, Innovations in Ophthalmology 2010 A review of the various stages of development of this preloaded
system by its designer, C. Pagnoulle, R&D Director at
PhysIOL. Refractive aspects of cataracts - Towards customization P. Rozot and JC Rigal-Sastourne. European Ophthalmic Review. Volume 3, Issue 2
Results of a prospective multicentre study on spherical aberration, contrast sensitivity and depth of field after implantation of a Micro AY IOL. Résultats avec l'implant MicroSlim à 2 ans D. Deidier. Réflexions Ophtalmologiques, N° Spécial novembre 2009, Tome 14 L'auteur présente les résultats d'une étude prospective menée sur 85 patients. Résultats de l'étude multicentrique sur l'implant Micro AY JC. Rigal-Sastourné, D. Deidier, P. Rozot, G. Lesieur. Réflexions Ophtalmologiques, N° Spécial novembre 2009, Tome 14 Cette étude évalue la qualité de vision obtenue sur 124 cas trois mois après implantation. 
Read full article
Read full article
Lees dit artikel
Lees dit artikel
Why use a hydrophilic acrylic IOL in 2009?

G. Lesieur. Cataract & Refractive Surgery Today. Insert. Oct 2009
The author outlines his views and provides clinical data on hydrophilic acrylic IOLs.
IOL centration and stability

C. Chassain. Cataract & Refractive Surgery Today. Insert. Oct 2009
The author describes a new IOL design and presents his clinical results on centration and rotational stability.
Photoprotection and photoreception with blue-light-filtering IOLs

B. Mashhour. Cataract & Refractive Surgery Today. Insert. Oct 2009
Point of view and clinical experience of a posterior segment surgeon on blue-light-filtering IOL
Small incision bimanual phaco chop

J.C. Vryghem. Cataract and Refractive
Surgery Today. April 2008
The author describes his bimanual procedure and the instruments used for capsulorhexis and phaco chop.
Klinische prestaties van de micro-incisielenzen van PhysIOL

De resultaten na
2 jaar van 52 ogen waarin een micro-incisielens van PhysIOL werd geïmplanteerd,
hebben aangetoond dat de gecorrigeerde gezichtsscherpte stabiel is: 0,92 na 1
maand, 0,94 na 3 maanden, 0,93 na 6 maanden, 0,92 na 12 maanden en 0,91 na 24
maanden. In deze studie werd geen enkele capsulotomie of behandeling met de Nd:Yag
laser uitgevoerd binnen de twee jaar na de ingreep.
Lees dit artikel (in het Frans)
Chirurgische prestaties van de micro-incisielenzen van PhysIOL
124 ogen aangedaan door seniel of preseniel cataract werden geopereerd door 4
chirurgen. 74,2% van de ingrepen werd uitgevoerd met biaxiale MICS-techniek en
25,8% met coaxiale MICS-techniek. De Micro AY-lens werd in 74,2% van de gevallen
geïnjecteerd via een incisie kleiner dan of gelijk aan 1,8 mm. Tijdens de
operatie werd geen enkele complicatie opgemerkt.
Lees dit artikel
(in het Frans)